Foundation and anchor bolt manufacturing
Foundation Bolt Manufacturer in India
Lohar Forging accepts foundation bolt manufacturing enquiries for J, L, straight and customer-drawing anchor assemblies. Send the approved foundation/base-plate layout with thread size, overall length, projection, material, finish and hardware. The project designer sets embedment and anchor-system resistance.
Dimension key
Read the foundation bolts dimensions
Identify the pattern first. A DIN 529 Type B cranked anchor is not the same geometry as a J hook, an L bend or a straight anchor rod with an end plate. The drawing should separate overall length, exposed projection, thread length and embedment. Include nut/washer arrangements, sleeves, plates and the template hole layout so the complete bolt set can be checked.
Standard size reference
DIN 529 Type B anchor bolt reference dimensions
Standard thread and anchor-head references help identify a specified pattern. Customer drawings control complete foundation assemblies; custom layouts have no preassigned dimensions on this page.
This table applies only to the DIN 529 Type B cranked-anchor reference. It must not be used as a J-bolt or L-bolt bend schedule. Overall length, embedment, projection, template spacing and assembly details follow the customer's approved design. Dimensions alone do not establish concrete-anchor resistance.
Dimensions are nominal reference values, not a stock list or a guarantee that every material/size combination is available. Specify the named standard and edition, material, finish and quantity in your enquiry. Manufacturing and inspection follow the agreed order or approved drawing.
Straight answer
How to specify a foundation bolt assembly
Foundation bolts are ordered to a civil and equipment interface, not just a thread size. Send the base-plate and foundation drawings, anchor pattern, material grade, projection and template requirement. Lohar Forging can review drawing-based bolt enquiries; engineering of the concrete anchor system remains with the project designer.
Product scope
J, L, straight and plate anchor configurations
J-shaped, L-shaped, straight and threaded-end arrangements are common drawing families. The correct pattern depends on the anchor design, installation method and space available below the base plate. A bent anchor should not be substituted for a headed or post-installed anchor without project approval.
Engineering selection
Thread, projection, embedment and template layout
Confirm the bolt circle or coordinate layout, overall and embedded lengths, projection above concrete, threaded length, plate and washer dimensions, sleeve or template and grout allowance. The designer must evaluate tension, shear, edge distance, concrete strength and installation tolerances. Accurate setting-out is as important as the steel part.
Technical analysis
Why anchor shape and embedment must match the design
Anchor geometry is controlled by the approved civil interface. Projection, template coordinates and grout thickness should be checked together before dispatch. An anchor with the correct steel grade can still be unusable when it misses the base-plate holes or lacks the specified embedment. Site installation and concrete capacity remain the designer’s responsibility.
Manufacturing review
Customer drawing review before manufacturing
A manufacturing enquiry is checked against drawing revision, material specification, bend geometry, threading and finish. If a template or matched nut-and-washer set is required, show it as a separate line item. Dimensional inspection can focus on anchor spacing, thread fit, overall length and projected length before dispatch.
Evidence and inspection
Inspection, traceability and order documentation
Ask for material documentation, dimensional records and coating records when the project requires them. Do not infer anchor capacity from rod grade alone: base plate, concrete and embedment design govern performance. Installation torque and grout sequence should come from approved civil and structural procedures.
International procurement
Export specifications and packing details
For international EPC orders, use a controlled drawing register and clearly label each anchor set by equipment tag or foundation number. Specify metric/inch units, destination packing, template details and the exact document dossier required for site acceptance.
Ready to enquire?
Technical RFQ checklist
A complete first enquiry helps us discuss fit, supply scope and documentation without guessing.
- Approved foundation and base-plate drawings
- J, L, straight or custom anchor pattern
- Diameter, pitch, length and projection
- Material grade and coating
- Nut, washer, sleeve and template
- Anchor coordinates and tolerances
- Quantity, tags, documents and destination
Related product families
Choose the page that matches the component, rather than treating different fasteners as interchangeable.
Related buying guides
For a deeper answer to a specific engineering question, start here.
Engineering reference
For specification research, see ASTM F1554 — anchor bolt specification. This external reference does not mean that every listed product is certified to it. Confirm the applicable edition, product rating and required documents in your approved purchase specification.
Quick Summary
Foundation bolts connect equipment or structures to a concrete foundation. Their shape, embedment and setting-out must follow the engineer-approved design.
Key Takeaways
- Approved foundation and base-plate drawings
- J, L, straight or custom anchor pattern
- Diameter, pitch, length and projection
- Material grade and coating
Made to your approved requirement
Custom foundation bolts: send your drawing or layout
For a custom part, email your drawing or layout to sales@loharforging.com, send it on WhatsApp, or call +91 98330 72266 to discuss the requirement. We confirm the drawing revision, material, finish, quantity and inspection scope before manufacturing. Custom dimensions come from your approved drawing; the reference tables below do not define a custom component.
- J, L, straight, plate or specified anchor pattern
- Thread diameter, pitch and length
- Overall length, projection and embedment from approved design
- Template, sleeves, plates, nuts and washers
- Material, finish, quantity, drawing revision and documents
Company and order verification
Manufacturing information and documents
Product information is maintained by Lohar Forging & Engg. Works, Mazgaon, Mumbai. This page was updated on 14 November 2026 with standard-reference dimensions and ordering guidance.
See our company and manufacturing profile and inspection and documentation process. The company publishes Government of India IEC 0315056487; view the published IEC document. The scanned record is historical; confirm current company particulars and required documents with the sales team.
An IEC is an import/export registration, not a product test certificate. Request the applicable material, dimensional, coating or lifting documentation for your exact order. Confirm the scope and validity of any required quality-system certificate with the team.
Related foundation bolts products and technical guides
FAQ
Foundation Bolts: frequently asked questions
Can I order foundation bolts from a thread size only?
No. The foundation design must define anchor pattern, embedment, projection, material, finish and associated hardware. Share the approved drawing.
Do you supply anchor templates?
Include the template drawing and quantity in the RFQ. Availability and manufacturing feasibility can then be confirmed with the bolt set.
Who determines the anchor load capacity?
The project structural or civil engineer should design and verify the complete anchor system, including concrete, edge distances, base plate and installation.
What details are needed for foundation bolts?
Send approved foundation and base-plate drawings, anchor pattern, diameter, projection, material, finish, nuts, washers, template details and quantities. The structural designer must confirm anchor capacity.
Are all foundation bolts made to one standard set of dimensions?
No. A named standard defines a specific pattern and dimensional scope. J, L, straight and plate assemblies have different geometry. The customer drawing defines project-specific length, projection, embedment and template spacing.
Do you decide custom foundation bolt measurements in advance?
No. Send the customer-approved layout or drawing by email or WhatsApp. Lohar reviews the specified dimensions and manufactures against the agreed requirement.
Does the dimension table establish anchor load capacity?
No. The structural designer checks the complete system, including concrete, embedment, edges, spacing, base plate and loading. This reference table describes geometry only.
Explore related manufacturing and product ranges
- Eye bolt manufacturer in India
- U bolt manufacturer in India
- Industrial bolt manufacturer in India
- Hex bolt manufacturer in India
- Stud bolt manufacturer in India
- Swivel lifting eye bolts
- SS shackle manufacturer in India
- Turnbuckles
- Wire rope pulleys
- MS shank hooks
- Nut bolt manufacturer in India
- D shackle and bow shackle manufacturer